Bulk Water Meters supplied by METEC
 
 
Bulk Compound Meter WPV-MFD (Models 226/216)
Model 226
 
Application
• Meter for measuring heavily fluctuating flow rates
• Overall lengths similar to Woltman meter WS
• Adjustable extension piece type 626 (accessory) available for adapting to DIN overall length
 
Features
• Compact length
• Cold water up to 30 °C (safe up to 50 °C)
• Carbide bearing
• Nominal diameter DN 50 - 150 mm
• No measuring errors in the switch-over range
• Easy installation
• Good long-term measuring accuracy
• Simple stocking of spare parts
• Low weight
• Integral part of the FLYPPER® system
• In order to secure a safe switch-over the WPV needs a minimum ingoing pressure of 0.6 bar (6m Wg)
 
 
Design
 
• Main meter with removable measuring insert and multifunctional counter (MFD)
• Complete head unit with counter and sensors can be rotated by 350° for easier reading
• Wet- or dry-running bypass meter
• Position of bypass meter: on right of main meter in direction of flow
• Operating pressure: up to 16 bar
• Installation position: horizontal
• Flange for PN 16
• Calibration to EO 6 (calibration regulations)
• G 1/2 flushing connection in bypass line
 
 
 
Special Versions
 
• Bypass meter on left
• Special flange holes
• For installation in any position
• Integrated outputs for remote reading and flow rate measurement
• Other models as bypass meters
 
 
 
Note
 
Main and bypass meter also available with the FLYPPER® electronic counter module in IP 68 (waterproof up to 5 m).